ScienceLine Plus MIC AMF Micro pH Electrode - SI Analytics

ScienceLine Plus MIC AMF Micro pH Electrode - SI Analytics

  • SKU: 285101330
Request a Quote

Sign In or Register to view prices and add to cart

  • Description

    Platinum Diaphragm - Cylindric Membrane - Micro Electrode - Silamid® Double Reference System

    ScienceLine Plus MIC AMF: ScienceLine Plus pH micro electrode with platinum diaphragm and Silamid® double reference with silver-ion trap.

    ScienceLine Plus pH "micro" electrodes are specifically designed for measuring small, valuable or rare samples in narrow vessels such as NMR cells. ScienceLine Plus micro pH electrodes have an extended shaft that narrows from 12 mm to just 5 mm in diameter at the measuring end; the narrow part is 130 mm long.

    Variants
    Art.-No. Name Content
    285101330 SCP MIC AMF S7 plug head, without cable
    285101335 SCP MIC AMF DIN Pt 1000, 3 m fixed cable with waterproof DIN plug and 4 mm banana plug
    285101340 SCP MIC AMF BNC Pt 1000, 3 m fixed cable with BNC plug and 4 mm banana plug

    ScienceLine Plus - Precision in every application

    In very demanding cases, off-the-shelf pH electrodes are just not quite good enough for certain samples or measurement conditions. These instances include (but are not limited to) measuring the pH of highly alkaline samples, samples containing sulphides or proteins and, for practical purposes, measuring the pH of a small sample quantity when in a small or deep vessel such as an NMR tube.

    Our ScienceLine Plus range of pH electrodes meets the needs of these challenging conditions.

    • Micro electrodes
    • Platinum diaphragm
    • A-Glass
    • Silamid® reference system with silver ion barrier and double-electrolyte for faster, more stable results and a longer electrode lifespan

    What makes ScienceLine Plus better than ordinary pH electrodes?

    Unlike many pH electrodes that use chlorinated silver wire to form a silver/silver chlorine reference system (diaphragm) that degrades over time when in contact with certain sample types, all ScienceLine Plus series electrodes employ a Silamid® double reference with silver-ion trap that facilitates universal use, even in protein or sulphide containing samples. The diaphragm itself is a maintenance free encapsulated gel system, and the silver coating of the inner tube has significantly larger (5x) silver surface compared to the silver wire system making for a faster, more stable and longer. The outer bridge electrolyte consists of the proven 3 mol/l KCl, which may also be replaced by other bridge electrolytes if need be.

      Overview Page ScienceLine Electrodes

    Here you can find out more about choosing the right pH electrode and answers to your questions:

     Blog: Which pH electrode do I need?

     Blog: What is pH?

     Blog: Calibration and adjustment of a pH electrode

  • Specifications
    ScienceLine Plus SCP MIC AMF SCP MIC AMF DIN SCP MIC AMF BNC
    Article number 285101330 285101335 285101340
    Sensor shape Cylindric
    Shaft Glass
    Diaphragm Platinum wire
    Temp. Sensor - Pt 1000 Pt 1000
    Reference System KCl 3 mol/l, Silamid® double reference with silver-ion trap
    Membrane Resistance 500
    Measuring Range 0…14 pH
    Temperature Range -5…+100 °C
    Shaft Length 70/130 mm
    Shaft Diameter 12/5 mm
    Connection S7 plug head, without cable 3 m fixed cable with waterproof DIN plug and 4 mm banana plug 3 m fixed cable with BNC plug and 4 mm banana plug

Downloads

  • handbook

    pH Handbook (English)

    A guide with helpful practical tips

    Contents:

    • Basic concepts of potentiometry and pH measurement
    • Structure of pH electrodes
    • Potentiometry of the pH electrode
    • Buffer solutions and safety in pH measurement
    • Measuring equipment and measuring set-up
    • Practical pH measurement
    • Recommendations for use, maintenance and care of electrode

    Titration Handbook (English)

    A guide with helpful practical tips

    Download Titration Handbook

    Content:

    • Basics of titration
    • Volume measurement devices, manual and automatic titration
    • Sample handling
    • Sensors and reagents
    • Titration parameters and calculations
    • Applications / Photometric titrations / Karl Fischer Titration / Verification of the titration