ScienceLine Plus SP Penetration pH Electrode - SI Analytics

ScienceLine Plus SP Penetration pH Electrode - SI Analytics

  • SKU: 285101350
Request a Quote
  • Description

    ScienceLine Plus SP Penetration pH Electrode - SI Analytics

    3x Ceramic Diaphragm - Spear - Penetration Measurements - Silamid® Double Reference System

    ScienceLine Plus SP: ScienceLine Plus pH penetration electrodes with 3x ceramic diaphragm and Silamid® double reference with silver-ion trap

    Variants
    Art.-No. Name Specifications
    285101350 SCP SP A DIN 3 m cable with water-proof DIN plug and 4 mm banana plug
    285101355 SCP SP A BNC 3 m cable with BNC plug and 4 mm banana plug

    ScienceLine Plus - Precision in every application

    In very demanding cases, off-the-shelf pH electrodes are just not quite good enough for certain samples or measurement conditions. These instances include (but are not limited to) measuring the pH of highly alkaline samples, samples containing sulphides or proteins and, for practical purposes, measuring the pH of a small sample quantity when in a small or deep vessel such as an NMR tube.

    Our ScienceLine Plus range of pH electrodes meets the needs of these challenging conditions.

    • pH electrode with spear-shaped membrane for penetration measurements
    • 3x ceramic diaphragm
    • A-Glas
    • Silamid® reference system with silver ion barrier and double-electrolyte for faster, more stable results and a longer electrode lifespan

    What makes ScienceLine Plus better than ordinary pH electrodes?

    Unlike many pH electrodes that use chlorinated silver wire to form a silver/silver chlorine reference system (diaphragm) that degrades over time when in contact with certain sample types, all ScienceLine Plus series electrodes employ a Silamid® double reference with silver-ion trap that facilitates universal use, even in protein or sulphide containing samples. The diaphragm itself is a maintenance free encapsulated gel system, and the silver coating of the inner tube has significantly larger (5x) silver surface compared to the silver wire system making for a faster, more stable and longer. The outer bridge electrolyte consists of the proven 3 mol/l KCl, which may also be replaced by other bridge electrolytes if need be.

      Overview Page ScienceLine Electrodes

    Here you can find out more about choosing the right pH electrode and answers to your questions:

     News: Portfolio simplification WTW® und SI Analytics®

     Blog: Which pH electrode do I need?

     Blog: What is pH?

     Blog: Calibration and adjustment of a pH electrode

  • Specifications
    ScienceLine Plus SCP SP A DIN SCP SP A BNC
    Order no. 285101350 285101355
    Membrane shape Spear
    Shaft Glas
    Diaphragm 3x Ceramic
    Temp. sensor Pt 1000
    Reference electrolyte KCl 3 mol/l, Silamid® reference system with silver ion barrier and double-electrolyte
    Membrane resistance 500
    Measuring range 0…14 pH
    Temp. range -5…+100 °C
    Shaft length 120 mm
    Shaft diameter 12/8 mm
    Connection 1 m cable with water-proof DIN plug and 4 mm banana plug 1 m cable BNC plug and 4 mm banana plug