IQ SENSOR NET LogoOn this page we collect and reference all information that will help you

The System

IQ Sensor Network: System 2020 3G

IQ Sensor Network: System 2020 3G

  • For up to 20 digital IQ sensors in any order
  • Measuring network for large plants, BackUp controller function for higher operational safety
  • Ethernet/LAN interface and integrated webserver for easy network connection
  • Fast and easy software update and saving of logbook data, measured values and configurations for additional safety on a USB stick
  • Up to 3 portable and clear displays even in direct sun light
 

Download Brochure"System 2020 3G"

Outstanding among the Compact: System 282/284

Outstanding among the Compact: System 282/284

  • Multi-channel controller for up to 4 IQ sensors provides easy and low-cost expansion
  • Up to 20 parameters can be visualized at the same time
  • Perfectly suited to replace or add a single measuring point
  • Simple Data transfer and download with USB stick at every controller
  • Optional: Ethernet and RS 485 interface for network connection and fieldbus communication
 

Download Brochure "System 282/284"

The Single Parameter Measuring Point: System 281

The Single Parameter Measuring Point: System 281

  • Low-cost entrance into the digital measuring technique
  • For the parameters pH/ORP, D.O., Turb, Cond, TS or Sludge Level
  • Stable, robust and reliable measuring technique
 

Download Flyer "System 281"

 

Comparison of the IQ Sensor Net systems

To support you, we offer a tabular comparison overview of our systems. This overview is currently available as a PDF document. 

Download

With the modular IQ Sensor Net of the brand WTW, Xylem has set standards in the field of continuous on-line measurement. Meanwhile, Xylem can look back on a 20-year success history with ten thousands of systems and sensors sold. The development of the system has progressed steadily. The list of available parameter measured and the technologies for communication continue to grow. Based on instrument and sensor technology that has been field-proven many times over, IQ Sensor Net offers an impressive level of performance and flexibility that is unique in this form. 

The system can be optimally adapted to any conceivable measurement task, even under special on-site conditions. The IQ Sensor Net communication system allows the easy integration of multiple measurement locations. This results in a significant reduction in costs while maintaining full functionality. 

View all IQ Sensor Net products

Sensors and Analyzers for many measurement Parameters

Oxygen

Oxygen

Dissolved oxygen is determined digitally and – depending on the requirements – optically or electrochemically 

View products

pH/ORP

pH/ORP

The pH value – one of the most common measurement parameters – and the redox potential are determined digitally 

View products

Conductivity

Conductivity

The electrical conductivity is reliably determined with digital measuring cells in many areas of application 

View products

Turbidity/Suspended Solids

Turbidity/Suspended Solids

Both the turbidity and the solids content are determined digitally using optical measuring methods 

View products

Nitrogen

Nitrogen

The nutrient parameters ammonium, nitrate and nitrite are measured with ISE, spectral sensors or wet chemical analyzers – we have the right solution for every application 

View products

Carbon

Carbon

The organic load is spectrally determined and monitored using the parameters COD, BOD, TOC, DOC, SAC 

View products

Phosphate

Phosphate

The concentration of phosphate is reliably monitored with wet chemical analyzers 

View products

Sludge level

Sludge level

The boundary between settled sludge to the projecting turbid or clear water is determined digitally and optically 

View products

 

Color

Sensors to continuously monitor color at wastewater treatment plant outlet and in surface waters 

View products

 

Planning aids for plant constructors and engineering offices

Product overview, technical data, tender texts etc.  

To the page

 

The new Solution for your Drinking Water Monitoring

A combination of proven technology
IQ Sensor Net + IDS (Intelligent Digital Sensors) = WTW Drinking Water Panel

  • Digital communication
  • Modern & clear panel design
  • Low flow rate
 

Learn more

SOFTWARE AND UPDATES FOR THE IQ Sensor Net

Download the latest version of software for the multi-parameter measuring system IQ Sensor Net:Xylem Analytics: IQ SENSOR NET Software Update (Logo)

Softwareupdate IQ SENSOR NET "Update Pack (L1)", V2.31

Version history – innovations:

  • V2.31 (12.07.2024)
    • Controller: Update required for following functions
    • MIQ/IDS: Additional connectable IDS sensors SensoLyt® 900-P, TetraCon® 925-3 and FDO® 925-3
    • UV/VIS sensors:
      • Additional wavelengths 436 nm, 525 nm and 620 nm for color sensors
      • Additional measuring range 0 … 500 mg/L for COD (5 mm)
      • Multi-point calibration CarboVis® (contact TechSupport)
      • Language updates for Dutch, Spanish and Czech
    • TriOxmatic® 700 IQ
      • SensLeck function can be deactivated
      • Dutch language added
    • Minor general improvements
  • V2.30 (01.07.2024)
    • Production relevant update

  • V2.29 (29.02.2024)
    • Production relevant update
  • V2.28 (31.01.2024)
    • Release MIQ(IDS modules
    • Minor general improvements

  • V2.27 (04.12.2023)
    • Alyza: Optimized Cleaning cycles
    • Dutch language added for VisoTurb® 700 IQ and ViSolid® 700 IQ
    • Minor general improvements

Download ZIP file


Files for PLC

EtherNet/IPTM EDS file, Version 1.2

File is needed on PLC to detect the IQ Sensor Net module MIQ/MC3 and of System 282/284

Download EDS file


PROFIBUS GSD file (for current IQSN Software), Version 1.24

File is needed on PLC to detect the IQ Sensor Net with software version ≥3.50:

  • DIQ/S 282-PR(/24V)
  • DIQ/S 284-PR(/24V)
  • MIQ/MC2-PR
  • MIQ/MC3-PR
  • MIQ/2-PR
  • MIQ/3-PR
  • DIQ/S 182-PR(/24V)
  • DIQ/S 182 XT-4-PR(/24V)

Download GSD file


PROFIBUS GSD file (for older IQSN software and controller), Version 1.22

File is needed on PLC to detect IQ Sensor Net with software version <3.50:

  • MIQ/MC2-PR
  • MIQ/2-PR
  • DIQ/S 182-PR
  • DIQ/S 182 XT-4-PR

as well as for the older controller modules:

  • MIQ/MC-(A)-PR
  • MIQ/(-A)-PR

Download GSD file


PROFINET GSDML file, version 2.1
File is needed on PLC to detect the IQ Sensor Net System 282/284 and the MIQ/MC3.
Required until PNIO version 2.0

Download GSDML file, version 2.1


PROFINET GSDML file, version 2.41
File is needed on PLC to detect the IQ Sensor Net System 282/284 and the MIQ/MC3.
Required from PNIO version 2.2

Download GSDML file, version 2.41


PC software for remote control

IQ Software Pack Connect, Version 1.00

For network connection. Only for the MIQ/MC2 controller.

Includes the following programs for remote access to the IQ Sensor Net:

  • IQS PC Terminal Connect for remote access to the IQ Sensor Net
  • IQS Datalog Transfer Connect for data transfer from IQ Sensor Net to the PC
  • IQS ConvigSafeLoad Connect to backup and reverse backup the configuration data of the IQ Sensor Net

Download ZIP file


 

 

 

REMOTE ACCESS TO THE IQ Sensor Net

When using MIQ/MC2, MIQ/MC3 or the System 282/284 (with Ethernet interface), remote access is available via our integrated web server IQ Web Connect. The remote access provides:

  • total control of the IQ Sensor Net
  • any time and worldwide
  • troubleshooting and remote assistance – without on-site visit
  • access protected by password
  • no licence, no extra cost

To connect the IQ Sensor Net to a local network or the internet, please reffer to the respective manuals, chapter 6:


 

 

 

Declaration of conformity (CE and UKCA)

Here you will find the EU Declarations of Conformity (CE) for the IQ Sensor Net for the European Union and the UK Declaration of Conformity (UKCA) for Great Britain, which has been in place since Brexit.

  • EU Declaration of Conformity IQ Sensor Net
  • UK Declaration of Conformity IQ Sensor Net
  • EU Declaration of Conformity Cables SACIQ and SNCIQ
  • UK Declaration of Conformity Cables SACIQ and SNCIQ

Download zip archive

 

Contact Us

If you have any questions don't hesitate to get in touch 

Contact us

Oxygen measurement </br>with FDO<sup>®</sup> 700 IQ

Oxygen measurement
with FDO® 700 IQ

  • Calibration free sensor
  • Reduces energy and operational costs
  • Long lifetime of membrane cap
  • Precise results without drift
 

View details of FDO® 700 IQ

Ammonia & Nitrate measurement </br>with ISE sensors (e.g. VARiON<sup>® <em>Plus</em></sup> 700 IQ)

Ammonia & Nitrate measurement
with ISE sensors (e.g. VARiON® Plus 700 IQ)

  • Easy and fast matrix adjustment
  • Up to 2,000 mg/l NH4
  • Extremly robust electrodes
  • Compensation with K and Cl
 

View details of the ISE sensors

Reagent-free COD measurement  </br>with NiCaVis<sup>®</sup> 701/705 IQ NI

Reagent-free COD measurement
with NiCaVis® 701/705 IQ NI

  • No reagent consumption
  • Integrated ultrasonic cleaning
  • Extremely low in maintenance
  • Additionally BOD, TOC, DOC, SAC, UVT, Nitrate and Nitrite
 

View details of NiCaVis® 701/705 IQ NI

 

Consumables, Reagents and Standards for the IQ Sensor Net and further Process Instrumentation

These include for example sensor caps, electrodes, pH buffers or the chemistry for our analytical instruments to maintain your measuring operation. 

Overview

 

Accessories for the IQ Sensor Net System and further Process Instrumentation

For the IQ Sensor Net, WTW offers a wide range of mounting accessories. From channel, to tank, to pipe installation – from wall, to rail, to floor mounting. Besides ready-to-go sets ,we also provide the accessories as single scopes to enable any kind of individual demand for sensor and controller/module mounting. Our range of products contains mounting accessories for drinking water and further analog sensors as well. 

Overview

Close