• Labor-Leitfähigkeitsmessgerät inoLab® Cond 7310
  • Labor-Leitfähigkeitsmessgerät inoLab® Cond 7310

Benchtop meter inoLab® Cond 7310

  • SKU: 1CA300
Request a Quote
  • Description

    inoLab® Cond 7310 Analog Lab Conductivity Benchtop Meter

    inoLab® Cond 7310: Precise and high performance laboratory conductivity meter with GLP supportung functions for documentation measuring results

    Variants
    Art.-No. Name Description
    1CA300 inoLab® Cond 7310 Single unit with universal power supply, stand, manual, CD-ROM with software and USB cable
    1CA300P inoLab® Cond 7310P Single unit with built-in printer, universal power supply, stand, manual, CD-ROM with software and USB cable
    1CA301 inoLab® Cond 7310 SET 1 Single unit with 4-Pol TetraCon® 325, 0,01 mol/l KCl, universal power supply, stand, manual, CD-ROM with software and USB cable


    Highlights:

    • Convenient and safe operation via plain text menus
    • Documentation of all data via USB interface or optional built-in printer - fast and error-free
    • Suitable for measurements according pharmacopeia
    • Repeatable measuring results by active, automatic AutoRead function with automatic recognition of stable values
    • The sensor symbol informs about the status of the electrode
    • Graphic display with plain text menus for the convenient and safe operation

    The inoLab® Cond 7310 is highly suitable for all conductivity precision measurements connected with automatic documentation according to GLP/AQA in quality labs in all industries. It works with all modern WTW conductivity measuring cells to cover all applications. For the documentation, the serial number of the used sensor can be entered. Upon request, the measured values can be put out via the optional built-in printer.

      Overview page lab benchtop meters

  • Specifications
    Parameter Conductivity/Salinity/spec. resistivity, TDS
    Conductivity 0.001 µS/cm ... 1000 mS
    spezischer Widerstand 0.00 ... 199 MOhm cm
    Salinity 0.0 ..70.0
    TDS 0 ... 199.9 g/l
    Temperature -5.0 ... 105 °C
    Resolution Conductivity 0.1 µS/cm 
    Salinity 0.1
    Accuracy Temperature +/- 1 digit 0.1 K
    Accuracy Messwerte +/- 1 digit +/- 0.5 %

Downloads

  • Manuals
  • Software

    inoLab 7310, 7320 - Firmware Update - V1.32

    Recommendation: Because of continuous improvement of internal performance we always recommend using the latest firmware version.

    Firmware version after successful update:
    inoLab pH 7310 V1.21
    inoLab Oxi 7310 V1.19
    inoLab Cond 7310 V1.21
    inoLab pH/ION 7320 V1.10
    inoLab pH/ION 7320 V1.14

    Download and installation notes:

    The necessary cable for connection to PC via serial interface is included in the inoLab® set.

    Version history – innovations
    V1.32: Solves a problem with the second channel of inoLab® pH/ION 7320
    V1.31: Optimisation of the extensions of the display
    V1.28: Solves a problem with the representation of the menu screens
    V1.26: Various optimizations
    V1.25: Various optimizations
    V1.24: This update solves a problem in the calibration history. Please note: When installed except the current calibration the history will be deleted, if necessary, please make a copy!
    V1.23: Smaller debugging
    V1.22: Various optimizations for inoLab® Cond 7310
    V1.21: Optimization of AutoRead function


    MultiLab Importer-Setup32

    Software

    Version history – innovations

    V 1.25: MultiLab Importer (Excel Add-In for acquisition of measured data)

    • Allows measurement and data entry of barcoded sample-ID via PC-connected barcode Reader for Turb® 750, Turb 430® and photoFlex® Series

    V 1.24: MultiLab Importer (Excel Add-In for acquisition of measured data)

    • New: Includes now photometers and turbidity meter of pHotoFlex series, Turb 430 and Turb 750 models
    • General improvements

    V1.23: Enhancements for MultiLab Importer

    • New Download of OxiTop®-IDS measurement date possible (results and measurement parameters)
    • Enhancement at transfer of electrochemical measurement results.

    MultiLab Importer-Setup64

    Software

    Version history – innovations

    V 1.25: MultiLab Importer (Excel Add-In for acquisition of measured data)

    • Allows measurement and data entry of barcoded sample-ID via PC-connected barcode Reader for Turb® 750, Turb 430® and photoFlex® Series

    V 1.24: MultiLab Importer (Excel Add-In for acquisition of measured data))

    • New: Includes now photometers and turbidity meter of pHotoFlex series, Turb 430 and Turb 750 models
    • General improvements

    V1.23: Enhancements for MultiLab Importer

    • New Download of OxiTop®-IDS measurement date possible (results and measurement parameters)
    • Enhancement at transfer of electrochemical measurement results.

    Software Update Windows 10 VCP Driver

    VCP Driver, 
    MultiLine, inoLab, ProfiLine, HandyLab and Lab, 
    Software Update for Windows 10

  • Flyers / Brochures / Catalogues

    InoLab 7000 Serie (Flyer, German, 999081D)

    Flyer, 8 Seiten, German, 999081D
    "pH, ISE, LF und O2 Messen - Genau, Zuverlässig, Selektiv" 

    InoLab 7000 Serie (Flyer, English, 999081US)

    Flyer, 8 Seiten, English, 999081US
    "Measurement of pH, ISE, conductivity and dissolved oxygen - accurate, compliant and sensitive" 

    InoLab 7000 Serie (Flyer, Spanish, 999081ES)

    Flyer, 8 Pages, Spanish, 999081ES
    "Measurement of pH, ISE, conductivity and dissolved oxygen - accurate, compliant and sensitive" 

Related Products